Also, I used 2x100Ah deep cycle marine batteries + 2 additional batteries of unknown capacity, probably between 50 and 100Ah
Also, I used 2x100Ah deep cycle marine batteries + 2 additional batteries of unknown capacity, probably between 50 and 100Ah
Both charge batteries using pulses rather than a constant voltage which extends the lifetime of the batteries compared to a cheap automotive charger that would over time reduce the capacity of the battery), all of which is geared towards lead acid.
Most PWM or MPPT charge controllers I've seen only support lead acid (which come in a variety of configurations, some vented some not) and do not do li-ion, at least not out of the box. Theoretically they have the hardware to do it (my CC can do 12v, 24v, and 48v systems) but maybe not the software.
Lead acid batteries have been probably the most commonly used in renewable energy projects for a while due to their cost-density but li-ion seems like a superior choice if you can front the initial cost. I've been looking at them but also feeling like in 5-10 years there might be more alternatives so replacing lead acid batteries every 5-10 years seems better for me at this point.