I have cheap asphalt roof shingles (even so, $10K to replace them)- I did look into reflective shingles, but they were much more expensive, plus I had to consider resale value..
I have cheap asphalt roof shingles (even so, $10K to replace them)- I did look into reflective shingles, but they were much more expensive, plus I had to consider resale value..
In the mid-Atlantic where I live now, night temps don't drop more than maybe 10 degrees below daytime highs of ~90F. So bringing in the evening air via an attic fan puts the house at no less than a toasty 80 (with 70% humidity) -- still uncomfortable.
Of course in older, not-well-sealed housing the venting poses the risk of drawing cooler air from the house to the attic, negating much (or all) of the benefit. So their efficacy is very situational.
Though old houses often have attic fans, they weren't there to cool attics. That was the purpose of widowed attic gables or breathing slats under wood shingled roofs. Attic fans are there to cool the house interior, especially the hottest rooms on uppermost floors. That's why the intake of an attic fan is the highest point inside the house and not the lowest point inside the attic. Even then attic fans aren't intended to run for more than perhaps 30 minutes a day after sundown -- just long enough to replace the hot air inside the home with cool air from outside.
To vent an attic, the ideal air flow is to intake cool dry outside air from along the attic soffet, pass it along the underside of the hot roof sheathing, and have it exit high where attic heat is at its peak. And do this passively without a powered fan if at all possible.