> That 9 day and almost 14-hour rebuild means that using the WD Red 4TB SMR drive inadvertently in an array would lead to your data being vulnerable for around 9 days longer than the WD Red 4TB CMR drive or Seagate IronWolf.
The other 4TB drives they compared against completed in around 15 hours, meaning the SMR drive could potentially take 14x longer to rebuild a RAID.
Rather than ideal, a rebuild is actually the worst case scenario as the RAID may detect the drive as unresponsive as it scrambles to catch up and thus gets dropped, exacerbating the problem for the other drives in the array. This is HL2 Resonance Cascade bad.
- not all SMR drives seem to cause problems
- rebuilding on a non-fresh/cleard hard drive can have negative performance implications due to how SMR works
So my guess is that it's a problem with the firmware which can potentially be fixed. After which they could be used in a NAS, just aren't necessary as far as you might think. So I guess it's probably not looking too good for the lawsuites chances to cause much yield/discount.