Note: Don't take any of the specific numbers above as gospel. These technologies develop extremely quickly, so it's quite likely that my knowledge of typical error rates is out of date.
In any case, here's the relevant quote from the original link (to phys.org), before it was changed to the less technical press release, which doesn't mention any specific technologies used:
"The new project built on that effort, combining nanopore sequencing with other sequencing technologies from PacBio and Illumina, and optical maps from BioNano Genomics. Using these technologies, the team produced a whole-genome assembly that exceeds all prior human genome assemblies in terms of continuity, completeness, and accuracy, even surpassing the current human reference genome by some metrics."
And those error rate examples are way way too high - illumina is closer to Q30, which is a 1/1000 error rate[0]. 15% would result in an unusable sequence.
https://emea.illumina.com/science/technology/next-generation...
And yes, a 15% error rate does result in a sequence that is unusable for the purposes of actually knowing the sequence. But a bunch of really long reads with 15% error can still be used to resolve the large-scale structure of a sequence, and then the lower-error-rate Illumina reads can be aligned onto this large-scale scaffold in order to resolve the actual sequence. At least, this is my understanding of how these technologies are typically used together, and given the mention of PacBio, nanopore, and Illumina, that seems to be what was done in this case.
As of 2018 error rate for alignments with nanopore was around 3-6 percent
Single read accuracy is not as important for such projects. As coverage gets to 50-60X, expected assembly accuracy is Q30 on human.