Of course, thats truly only correct for a resistive load (but, without knowing much about induction stoves, its probably within 10% - modern power electronics are amazing)
[1] Root Mean Square. Basically the measure needed to make a simply multiplication give you the power. Other ways to measure line voltage are
Amplitude. This would be the A in V(t) = Asin(wt). A = sqrt(Vrms)
Peak to peak. This is 2xA.
They’re all useful ways to thinking of the same thing. If you’re designing insulation you’re designing for A, or peak to peak. If you’re designing a water kettle, you’re interested in Vrms.