Introducing cold, saturated air to your warm house will not, in general, make it feel nasty and humid.
While I don’t want the walls sweating, I could imagine there are industrial or commercial environments where moisture level matters a lot. Electronics plant: dry is always bad! Want some moisture to dissipate static. A library wants low, but not zero moisture. A manufacturing plant wants it to be very consistent. A fruit market wants its humidity high.
In a residential environment, it’s a toss up: some stuff wants to be dryer while other stuff doesn’t.
That link seems to be discussing a situation where there is too much humidity coming in relative to the amount of heat the A/C needs to remove, and that hits my pet peeve about air conditioning design. Air conditioners generally run at a roughly constant coil temperature, which means that there is no independent control over dehumidification versus cooling. If you happen to be at the design conditions, great. Otherwise you don’t end up with the humidity you want.
I know of one system (“dynamic humidity control” by Chiltrix) that adjusts the coil temperature to control humidity. As far as I know, any hydronic system can do this with minimal modification, but I don’t think it’s popular.
My "smart" thermostat has a settings for this, but I seem to be at its algorithm's mercy instead of specifying: "50% RH or less, no change, 50-70%, -2C to the set points, 70%+, -3C to the set points".
Let alone being able to do dehumidification only.
Heat recovery ventilation (HRV), which uses a sensible heat exchanger, is sufficient in temperate climates but otherwise you need to be able to transfer latent heat also to reduce humidity, so need the ERV.
It is like pouring 200ml of water from a 1000ml jug into a 200ml jug. Same water, higher % fillage (to use a technical term).