Turns out the magnetics on an Ethernet port are good at their jobs. Like, really good. Not quite telecoms lightning-strike-survival good, but up there. Mains 60Hz may as well be DC as far as these things are concerned, and they're explicitly designed to block DC. Sure, for some configurations of magnetics you can blow them up if you get the pin connections just right, but that requires you to do a lot more than just "connect the transmit pins of the RJ-45 to HOT on 110VAC and the recieve pins to Common". Because that doesn't work. And even when it does work, it just overheats and pops the magnetics, opening them. Nothing happens inside the device proper.
If you want to cause some real fun you need a hi-pot tester plus a ground bonder. Those can do things that shouldn't happen.
You posted this knowing someone would beg you to say more, right? What a tease. Fine. Say more.
It's more interesting when you break the tester itself. But then you have to fix the tester. These are not complicated machines (they're basically just transformers)... there's some complexity in regulating the outputs and more in making the measurements but most of the hard stuff is in having the tester itself survive the horrid abuse it's visiting on everything else around it.
Damned if I didn't end up being right. They had a clerk who was embezzling by creating false customer returns. Every time she made one she plugged the network into the mains. Her boyfriend apparently made this thing and told her that it would 'fuzz the system' or some other kind of idiotic idea. What it actually did was eventually start a small fire in the wiring closet.
So, yeah the effect of one of these things is gonna be highly dependent on the environment. The galvanic isolation of Ethernet is not any sort of guarantee. Though I can confirm that the Cisco gear stood up to unreasonable abuse, it was unequivocally damaged.
IIRC ethernet cable side is only magnetically coupled to the port/device side via small transformers. So running DC would probably just melt the cable or transformers but is not really likely to damage the device side (? Not actually sure about this).
But in this case it runs mains AC.. so... Do we expect the cable to blow first due to the high current, saving the device, or do would we expect the brief period of AC would cause enough induced current on the device side to also fry that?
Cables are a lot thicker than the electronics inside the port itself, so my bet would be, port goes first, probably fails in a way that disconnects the current, if not, the ethernet cable would probably compete with the circut breaker on who melts first (circut breakers, even if they're marked with (eg.) 20A on them, survive a much higher current for a short time, before they eventually fail, due to some electronics, especially motors and large lightbulbs act almost like a short circut when they're starting up).
> So running DC would probably just melt the cable or transformers but is not really likely to damage the device side (? Not actually sure about this).
A step of voltage, whether that's just turning on AC on top of the cycle or just pushing DC thru it would go thru the transformer in form of short spike.
So sure, looking at random transformer data they are protected to like 1000Vrms so it wouldn't jump thru isolation, but initial magnetic spike might, and then it is up to any surge protection on the other side to ground that
> But in this case it runs mains AC.. so... Do we expect the cable to blow first due to the high current, saving the device, or do would we expect the brief period of AC would cause enough induced current on the device side to also fry that?
I'd guess transformer would be the highest resistance/area thing in the chain so it would melt first.
The Etherkiller (2002) - https://news.ycombinator.com/item?id=8431936 - Oct 2014 (44 comments)
I would assume avoiding touching the Ethernet cable after power was attached to avoid touching potentially melting wire?
Are there any mitigating factors?
For example, https://www.amazon.com/TP-Link-AV600-Powerline-Ethernet-Adap...
I mean, compared to the humble USB Killer (which was inspired by the Etherkiller), this has a lot more oomph.
But they are designed for ESD protection, so while high voltage, not that much energy
The problem is that there is no fuses, while ethernet basically have transformer working as a fuse, USBkiller can hammer the protection diodes till they burn out and then the rest of it gets it.