A net-zero kerosene process will absolutely be a part of a carbon-free future and it's naive to assume otherwise.
A net-zero kerosene process will absolutely be a part of a carbon-free future and it's naive to assume otherwise.
I'm not sure what the EV story around these small-business focused vehicles are. Some professions, like commercial plumbers, would put a larger focus on cold weather performance than current EVs have. Some professions follow a pattern of going to a job site for an hour, and then go to the next one. They might be convinced if their total daily millage is within one charge or if they can charge at their job sites. Some uses of these vehicles are literally driving eight+ hours a day, and probably will be among the last to leave ICUs.
A net-zero kerosene? No, because it's a made up stuff, like Toyota's self-charging ICE cars or "clean" coal, gas or whatever.
BTW: Tesla just released a semi truck that does 500 miles fully loaded and it's a v1 technology. It's already good enough for most trucking and an EV semi 10 years from now will be both cheaper and longer range than that.
I'd wait for more Tesla semis on the road before agreeing with that SF to LA semi test. I think they can pull it off, but the economics should make sense.
For trucking, at least, a modular approach seems reasonable where some are all electric and some are hybrid where you chose the maximum generator output based on your expected duty cycle. A truck to lug cement over the Rocky Mountains on a daily basis will have a different load curve from one hauling across Texas.
Hybrid focused ICE engines will likely be quite different from those designed as the primary motivation for cars, and there are probably not many situations where a v8's the right size. (Hybrid where they only run a generator to charge a battery will likely be optimized for only a couple RPMs and loads intermittent operation, etc)
To get a better idea of the scope of the problem: take a semi with a 300 gallon tank that takes roughly 5 minutes to fill at a fast 60 gal/minute pump. In those 5 minutes, roughly 12.2MWh of energy is delivered into the semi. In other words, one diesel fuel pump today can deliver close to 144MWh of energy in an hour (assuming 50% idle time per pump). Which means that to replace 6 diesel fuel pumps, you would need upwards 864 x 1MW fast charge stations. Even dividing the energy delivery rate by 10 still leaves you with an 86MW capacity requirement for a single truck stop.
I think there's still a lot of work to be done before electrification of commercial vehicles on any large scale is viable.
The truck stops will have a few tanks of off-road diesel to run a generator to create electricity to charge the truck batteries.
Local energy storage for rural truck stops will be diesel in underground tanks, rather than diesel in truck tanks.