... so, a single pair PHY layer and a connector I have not seen before ...
https://www.panduit.com/content/panduit/na/en/landing-pages/...
... so, a single pair PHY layer and a connector I have not seen before ...
I don't care what you replace Ethernet RJ45 with, but make it a standard that is only used for Ethernet.
At the end of the day it's someone's job to actually run cable, terminate and test it, and attach equipment to it that people are responsible for. You have to remember that the physical cable plant is infrastructure itself whether it's connected to live equipment or not. There's already a big enough problem with people trying to do things like route display cables through buildings, for example - the workaround that I'm seeing a lot is that people are using specialized signal converters that send HDMI/DisplayPort over a pair of Cat5e/Cat6 cables, just so that structured cabling can use normal cabling/networking supplies (i.e. keystone jacks, patch panels, conduit sizes, testing/tools, etc.) without wasting so much time with planning for projectors/displays ahead of time etc.
RJ45 is for twisted pair cabling. It's not specifically for Ethernet. 802.3cg only uses 1 pair. If you use the center pair then it works for TIA-568A, TIA-568B, or USOC. It's great for experimenting since everyone already has twisted pair patch cables to play with. Barring that, just give me screws that I can put the wires into so I don't need to think about connectors at all.
See: USB over D-SUB, serial over RJ45, the wide range of proprietary protocols that cheap IDE cables were (and probably still are) use for today, and weird edge cases like reusing the sturdy DMX ports to power sex toys.
8P8C is fine for ethernet, it doesn't need replacing. Nobody uses it for telephony modems anymore and very rarely will an average user encounter a compatible plug that wasn't made for ethernet.
I'd rather see fringe use cases like serial over RJ45 use a better connector than to have to cut off, strip, and wire up a new connector for every new network appliance I'll buy in the next 10 years.
It's purely an analog device. Presumably they used USB because the cables are cheap, shielded, and have enough conductors for what they needed. (Probably ground plus signal wires for two linear pots and a pressure sensor.)
I hope they designed it so it doesn't fry something if you connect it to a real usb device, but I'm not inclined to try it.
I'm almost certain that serial has been in common use on 8P8C longer than 100BaseT.
Personally, I'll stop believing in that connector when it stops being useful.
Everyone (including me) still calls it RJ45 because "8P8C modular connector" is far too long a name.