I was once in a computer room at Stanford which had two large industrial AC/heat units. I was there to copy old backup tapes (alumni were saving some history) and had a lot of free time while the tapes spun. I noticed that one A/C unit was on heat, and the other was on cool. So they were wasting a vast amount of energy.
You're supposed to wire those units together so they cooperate. Their controller can do that. Nobody knew that.
When you have district heating, it makes sense to use steam for the reheats instead of electrical resistive heaters. There are also steam powered chillers, for places that don’t have district chilled water.
I asked the first quoter about all the other work #2 and #3 suggested and he scoffed at it and said he did not want to keep his guys working in my attic one second longer than necessary in the August heat and that the electrical work was completely unnecessary.
Similar to dentistry, they're doing something useful but it's hard to know how much of it is actually valuable
I strongly suspect if I had called for service, I'd be told I needed a new furnace, even though this one is less than a decade old.
If it was on the flue, then it's a symptom of a drafting problem when they fail. Basically the thing should rarely ever click, but if the flu isn't drafting well, then the snap disk will get triggered frequently. You'll never notice anything wrong because the heat still works fine.
Then the thing fails and you fix it, but you only fixed a symptom and not the problem.
Even so, I still think it's better to get in there and figure stuff like that out than to avoid it. "just let the professional do it and do whatever they suggest" only works if you have some way of finding a guy who is both knowledgeable and honest. Yeah there are obviously risks like being unaware of invisible unsuspected things like above, but life is risk regardless.
A high limit trip will generally cycle the furnace off for a time period. Somewhere between 3-5 off cycles will result in lockout and the furnace will stay off. The control for this is more likely to reside in the furnace board vs an aftermarket ui.
This results in higher efficiency and better steady state comfort as the heat is on for always 18+ hours and often 22+ hours per day. It’s hard to say with confidence on the precision, but it seems like this is saving 8-10% in gas (in therms) vs last year when I had a constant flow temp (that I’d adjust manually every so often to try to match but where I’d have to leave it “too high” or risk a cold house on the coldest days).
The exhaust temps in the stack reach steady-state far before even a 30 minute run would be finished.
This indicates you have a problem with temperature rise across the heat exchanger, probably from inadequate airflow. Your ducts may be sized too small/furnace too large, fan speed set too low, plugged filter, etc. You may be able to mitigate the problem by increasing fan speed, limiting heat by using stage 1 only, putting in less restrictive filter, add additional cold air return, etc.
Usually a failed limit switch means cycling and a bigger problem with airflow. However I have seen a high temperature limit switch fail without cycling - fell apart with age (40 year old furnace).
It took an extended run to get the house back up to temperature, but it had no problem with a correctly functioning switch.
Obviously not all HVAC is in the realm of a normal person's abilities, but much of it, and almost all problem diagnosis, only requires reading the diagram inside the furnace, using a multimeter, and a screwdriver or wrench.
It's all very trouble-shootable. If you have those basic skills you should be able to identify what exactly is causing the issue, and the tech won't be able to lead you down the garden path.
Balancing the HRV was done by some professionals once the install was done, and only required a manometer to adjust some wall vents and a baffle in the exhaust duct, which wasn't quite the same as heating/cooling calculations would be, since heating was hydronic and AC isn't really a thing in AK.
I'd add a tool for measuring temperature, ideally a digital psychrometer, but even something that just measures dry bulb is useful for heating and bad AC failure.
Finally a multimeter, ideally with clamp on amp readings.