> While giving a tour of the Toronto-Dominion Centre to a group of articling students, he attempted to demonstrate the strength of the structure's window glass by slamming himself into a window. He had apparently performed this stunt many times in the past, having previously bounced harmlessly off the glass. After one attempt which saw the glass hold up, Hoy tried once more. In this instance, the force of Hoy slamming into the window removed the window from its frame, causing the entire intact window and Hoy to fall from the building.
Pulling oneself up onto something by one's fingertips takes a lot of strength. Should have tried that beforehand. (It looks easy in the movies, but those stunt people are very fit.)
We don't generally design safety regulations around "should" and averages, but instead when edge cases happen, as the magnitude of the outcome is very important to take into consideration. I'm not sure what you're trying to express with your comment.
1: https://www.engineeringtoolbox.com/co2-persons-d_691.html
In a system like this, if the AHU stops for any reason, the whole floor is effected. Since chillers and associated equipment are very expensive, I would imagine the maintenance fees would be uncomfortable. (get it? Sorry.)
(In NYC, we all agreed to believe that there is no such thing as residential air conditioning that is not in the form of a window unit, however.)
The residential stories have casement windows, within the curtain wall, that can swing up to 4 inches (100 mm) outward. In addition, some condominium units have motorized windows at least seven feet (2.1 m) above the floor.[1]
The condominiums start on the 32nd floor, according to the same article.
If building can't easily be retrofitted to allow openable windows, then I would assume they either can't be used for residential or they could try to get some sort of exemption if they can prove it's safe. I'm mostly going off what I know about building codes and what I've read previously on the topic when it's posted and it's delved into what the actual problems are in converting to residential.
Commercial building windows in general do not open at all.
The problem is not that every window needs to open, it's that some windows need to open. In the building codes I've seen in the past for residential homes, that was expressed as a percentage of square feet of the room or entire building.
So, are you saying there are plenty of tall condos where no windows in a specific dwelling open, or that they have some windows that don't open? If they have no windows that don't open, do you mind mentioning where, as I'd be interested in what the solution was to the problem of needing to allow for passive ventilation.
My friend owns a condo in Vancouver. No windows open.
Also Seattle: https://www.reddit.com/r/Seattle/comments/s2s7bx/cant_open_a...
Also https://www.reddit.com/r/askTO/comments/omdxmp/downtown_unit...
It does appear to be that in New York it might be required though[1], so it's possibly still a problem depending on area. I'm not going to act like I'm an expert on reading building codes or that one in general though, so I could be misinterpreting it. SF had what clearly seemed like a mechanical ventilation exception in it when I just looked, but SF and Manhattan are the only things I looked up to compare to see if I could find whether it seemed fairly universally allowed or not.
1: https://up.codes/viewer/new_york_city/nyc-building-code-2022... and https://up.codes/viewer/new_york_city/nyc-building-code-2022...