You also just have issues like the low chance of having clear skies after a hurricane or a bushfire.
For disaster situation power, a diesel generator is still the cheapest and most reliable option.
Also, diesel and gas were pretty much inaccessible for the first 5 days of the disaster, so unless you have a stockpile that's been treated for longevity, you might not even be able to run your whole home generator for long.
Is this a thing IRL? Every system I've looked at stops feeding the grid as soon as the grid goes down
But that's more a policy decision than a technical restriction. We could change it so power can flow on both sides of a fault instead of only the "upstream" grid side.
a) government mandates that turn over existing grid infrastructure to such a project, because the existing grid infrastructure is almost all privately owned
OR
b) building new infrastructure to create an isolatable local grid
Neither of these seem particularly likely to me.
This is so those F150s are not backfeeding the wires while a repair crew is trying to fix it.
Ergo, if the local grid is "taken out", those F150s cannot be "on the local grid".
The lightning extended range has a 135 kwh battery and can backfeed 90A@240V. That's a heck of a lot of power.
Yes, and sort of.
Inverters will prevent power flowing to the grid if the grid is off. However most inverters will continue to supply power into the house while the grid is off.
There are various factors in play here, and you need to do proper homework, but certainly a fraction of the house can be powered, if not all of it.
I'm not sure if this is "special" inverter or not. Every one I researched had the same functionality.
The shelf life of diesel is about a year; the shelf life of propane is effectively unlimited.