Steam Networks
worksinprogress.co
worksinprogress.co
Electrical transmission systems are roughly 85% efficient to the consumer; together with boring old resistive electric radiators which are 100% efficient. So is there any reason to subscribe to the steam system for new construction?
What does this mean? Are you imagining a future where individual houses have their own nuclear plants? Or where nuclear plant workers live on-site?
I'm get the argument that we should have more nuclear power, and that some future reactors may be small, but I don't understand the expectation that they would be close enough to residences to pipe steam.
In such tighter conditions, you can easily have enough inhabitants per km² that it would justify building small mobile nuclear reactors.
Who would like to live next to a reactor if it can melt down? Well, you have reactors using fuel pellets locked in marbles that due to their diameter can never meltdown.
- https://newatlas.com/energy/oklo-aurora-nuclear-microreactor... - https://www.popularmechanics.com/science/a33896110/tiny-nucl... - https://www.nuscalepower.com/products/nuscale-power-module
They target from home to residential scale. I hope they are eventually a thing.
This is actually terrible and supports their point. Heat pumps are not sized as if they were running at a mere 100% or less, they are sized for the btus they normally produce, and aim to run close to 100% of the time, meaning they will be too small and not be able to do the job when they drop below 200-300% efficiency, unless they are grossly oversized. That leads to short cycles which makes condensation and moisture in the summer and wear and tear all year and less electrical efficiency because starting a pump and blower costs more than running it.
Current inverter types that can run slow do allow them to be oversized but it's still not great. Those are more expensive and have more failure points in electronics too.
Also either need very expensive oversizing or backup heat sources to compensate reduced heat output, even if you get occasional cold spikes.
Unfortunately nothing in life is as simple as it first seems.
I won't try to make his case here, but he is pretty convincing that a reasonably sized heat pump system can be sufficient even in very cold climates (by US standards).
I would reccommend keeping backup heat source when installing heat pumps into older homes. A simple wood stove, used during cold spikes, could be enough.
My country has subsidies for heat pump installations into older homes and it had requirement to get rid of chimneys to get that. After the whole europe energy crisis thing, this requirement is gone now. Turns out having alternatives is a good thing :)
Out two tonne heat pump works just fine even at -25C this past winter.
We still have a natural gas furnace but our gas usage is down 65% despite this winter being colder than last year’s.
Tell me again how heat pumps don’t work in colder climates?
It is easy to see the loss of something old. However the opportunity cost from not building new is something that is very hard to get people to understand.
Sure, you can still find good weather heat pump that crap their pants near or under freezing. However, the majority sold here in Europe still stay well of 200% down to -15C, some even -25C.
> Most electricity is generated by using steam to turn turbines
That is true. It is also true that renewables usually do not use steam. But they don't answer for "most electricity". That's natural gas, coal and other types of thermal plants, including nuclear.
Gas combined cycle power plants get part of their power from gas in the turbine directly, and part of it from steam cycles. I can't figure out what % over of power comes from which part, and not all gas power plants are combined cycled.
It seems reasonable to say that most electricity is not generated by steam turbines. However I'm not sure how to find the real data to verify this. (and pedantically the gas in a gas turbine is mostly steam)
https://en.wikipedia.org/wiki/Hydrogen-cooled_turbo_generato...
I am not sure about "always". Does it not depend on the temperature difference?
The use cases for steam seem to be where you need more than room heating though: the first paragraph mentions sterilising medical equipment, humidity control, and washing.
I don't know of any of the customers of the steam system in downtown Vancouver that use it for sterilization purposes, it connects almost exclusively large office towers. There's no hospital or medical facilities connected to it.
My understanding: A heat pump is always better than resistive electric heating. Sometimes a outside air using heat pump needs to use extra energy to defrost the outside unit (with resistive electric heating). The defrosting is driven by sensors, but rarely happens more than e.g. once an hour for 5 minutes at a time. Heat pumps really do win over resistive electric heating on everything except initial cost, and that's not even hard -- resistive electric heating is very wasteful.
Electrical generation itself isn't a 100% efficient. For example a gas powered electricity plant is about 60% efficient for generating electricity. Generating heat from gas is far more efficient.
Then again if you use the electricity not for direct heating but for example to power a heatpump on the other end (i.e. you use the electricity to extract heat from the air) then it could be more efficient.
There's zero opportunity cost of "you could use it for some other purpose instead".
Wikipedia says "Approximately 30% of the ConEd steam system's installed capacity and 50% of the annual steam generated comes from cogeneration" i.e waste steam, which is .. half good, I suppose.
It also gives https://web.archive.org/web/20101207021857/http://coned.com/... which I guess has the rest of the details in.
That said, I think most of this applies to heated water, not steam.
But they're only about 33% (old tech) to 45% (best-case new tech) efficient when it comes to thermal potential. Burning coal or natural gas produces lots of heat, and while some of that heat turns the turbine, there's still a lot left that gets lost to the condenser or to the exhaust flue and atmosphere.
However, that's where steam distribution is awesome: It enables cogeneration, where some of the waste heat from electricity production can be efficiently used by heating industries. The electrical plant requires supercritical steam at 1000F and 1000 PSI, but the steam network only needs steam at ~150 PSI and 350F, which still has a lot of energy in it from the burners but is of comparatively little use to the turbine.
Almost all electricity run through computers are basically resistance losses at the end of the day, so data centers and crypto miners on the other hand...
> Typically, high-voltage transmission lines are designed to operate at temperatures of around 75 to 100°C (167 to 212°F). However, under heavy loads, they can sometimes reach up to 150°C (302°F), but this is usually the upper limit for safe operation.
If that's a core temperature then the insulation might not make it significant, but if the outside leaks this much... I might not mind paying myself for a plastic tube and a fan to use around the line if I lived near one. Okay okay, it'll be more complicated than that, but still: free energy? And you're doing the power company a favor by decreasing the resistance in the case of most metals (https://www.engineeringtoolbox.com/resistivity-conductivity-...) including copper which https://en.wikipedia.org/wiki/High-voltage_cable says they're made of
Beyond that, you're likely also decreasing the maximal electrical current the wires can carry, as they won't be able to dissipate the heat as effectively with the additionally insulation.
- insulating high voltage lines isn't trivial
- the conductor will be hot inside the insulation...
- service cost of either system will be increased (by rather a lot, I'd guess)
In modern co-generation you can for example burn gas in a gas turbine & produce electricity. Then heat water to steam with the gas turbine exhaust & power a steam turbine to get more electricity. And then the steam is condensed by the district heating water loop.
So in theory you will get more electricity & almost all the "waste" heat is used to heat houses.
The water isn't quite as hot as it needs to be when it arrives, so it's heated additionally in the building itself.
The article mentions a similar approach, with steam instead of water:
> They also purchase additional steam from a 322 megawatt plant in Brooklyn
So using electricity for heating would be just throwing free heat away. Heat distribution networks are of course not free though.
Electric heating would be an economical win if the electricity could be harvested by solar and wind generators, and stored. Storing solar heat directly is much trickier.
Steam with <1112 BTUs per pound vs room temperature will condense, so the heat value of a megapound of steam is at least 325,895 kWh. That's a marginal cost of 1 cent to 3 cents per MMBtu or 3.5 cents to 11 cents per MWh. The hookup cost ($3,555) is much smaller than the cost of the steam ($13k-$44k per the article).
For comparison natural gas costs a couple dollars per MMBtu and wholesale electricity costs $40-$60 per MWh. *The steam is orders of magnitude cheaper.*
If the article's quoted prices are accurate (note: Lincoln Towers seems to pay $2.43 per megapound, significantly less than the $11.35 usage fee the article gives immediately before. Not sure what's up.) then steam is practically free. I'm not really sure how that's possible; maybe there are subsidies or regulations enforcing production. A significant amount of the steam is from cogeneration, where steam is a byproduct of pollution-reducing processes- it makes sense that would reduce the cost, almost all steam would need to be a byproduct to explain the price.
I'm wary of attempting comparisons of end to end efficiency, just because these aren't apple to apple comparisons. Solar panels are 20% efficient. Nuclear power can be anywhere between 60 and 90% efficient. Coal plants can be between 35 and 50% efficient. Each of these can have an economic rationale despite these differences in efficiency.. A Dyson sphere with 0.001% efficiency could be a winning value proposition. Granted, these are energy sources rather than transmission infrastructure, but the point is the same.
I would want to know about the efficiency loss from whatever primary source of energy was generated before it gets transmitted across the electrical transmission infrastructure, and I would want to know how it compares to a steam source, which could plausibly be such a thing as waste heat. If your steam is cheap or potentially even free it could conceivably win out in the final assessment, even if it has higher relative transmission losses.
All that matters is the actual power generation since there's no marginal utility of "what else we would use that space for" (unless you're consuming farmland etc for the solar panels)
If the purposes are mixed, of course a photovoltaic panel can generate electricity for many purposes, while sunlight shining on a garden hose can only heat water. So it might be a more useful system, even more cost-effective, despite being much less thermally efficient.
It's the same with burning things to make heat, versus burning them for electricity and then using electric heaters.
> in 1962, the anthracite seam under Centralia, PA – 25 miles to the west of Lehigh County – caught on fire and is still burning today.)
That’s crazy to think that for over 60 years there’s been an underground coal mine on fire. I wonder how long the mines will burn for. The pictures on Google are quite interesting.
"Centralia has been used as a model for many different fictional ghost towns and manifestations of Hell. Prominent examples include Dean Koontz's Strange Highways and David Wellington's Vampire Zero."
Wiki says the fire started in the 1950's but CNN says 4 thousand years.
https://en.wikipedia.org/wiki/Yanar_Dagh https://www.cnn.com/travel/article/yanar-dag-azerbaijan-land...
https://www.dmr.nd.gov/ndgs/ndnotes/ndn13_h.htm and https://www.dmr.nd.gov/ndgs/documents/newsletter/2013Winter/...
> Several early explorers reported coal fires in the northern Great Plains region. Over the years, range fires have ignited lignite beds many times. In two places in western North Dakota, in Theodore Roosevelt National Park and near Amidon, lignite seams were recently burning for many years. A seam of lignite at Buck Hill in the park burned from 1951-1977.
And that's the modern history.
> Years ago, during fieldwork on the major buttes of western North Dakota, John Hoganson and I discovered clinker pebbles in the Arikaree Formation indicating that coals had been burning prior to when these rocks were deposited some 25 million years ago. Probably as far back as 40 million years ago, when grasslands were first established, fires have swept across the plains of North Dakota igniting coal seams.
> the second largest district steam system in the United States. The plant provides steam for heat and hot water to more than 200 commercial buildings and industries across downtown. Perry K's steam also helps power chilled water facilities which cool more than 60 large facilities around downtown. [1]
I grew up going to downtown Indianapolis as a kid and was always freaked out by the steam emanating from the manholes and grates on the street. It turned out not to be an unfounded fear--they have occasionally exploded [2].
0: https://en.wikipedia.org/wiki/Perry_K._Generating_Station
1: https://info.citizensenergygroup.com/thermal/history
2: https://www.wfyi.org/news/articles/locking-covers-installed-...
https://en.m.wikipedia.org/wiki/Mike_Mulligan_and_His_Steam_...
[1] https://www.swm.de/dam/doc/geschaeftskunden/fernwaerme/flyer...
[1] https://www.untappedcities.com/inside-roosevelt-islands-futu...
[2] https://www.untappedcities.com/pneumatic-tube-mail-new-york-...
Minneapolis: https://cordiaenergy.com/our-networks/minneapolis/
St Paul: https://www.districtenergy.com/
The 30-year-old steam network springs leaks every so often, so you see gurgling hot springs from the ground.
I’d love to know how much cheaper it would be to use this form of heating for my home compared to oil heat.
Eventually the city would like to make the system stop using natural gas, so there is a wood waste burning plant comming online at the end of this year & hot water pipeline is being built from the nearby Dukovany power plant. This two together should make the system natural gas indepedent in the future. :)
While it started as steam based system & powered most of then very important textile industry, steam also has issues. Old pipes loose quite a bit of heat on the way (there used to be evergreen meadows even in winter in places above the old steam pipes), the pipes flex quite a bit when heating up/cooling, so they need to be placed on rollers in underground channels with U shaped sections to account for the pipe stretching/contracting. The steam also condenses & you need to get rid of that condensate on the way. And while unlikely, it is possible for a steam pipe to burst/explode, which is very dangerous for any bystanders.
For these reasons & because the textile industry being much less important, the Brno district heating system is being converted to hot water distribution, which is quite a bit more effcient apparently. Reportedly, with modern insulated pipes, the heat loss on the way is negligeable, the pipes can be placed directly in the ground & they form a closed loop - no more mucking with rollers, condensante or explosions.
So in a few years, the often seen steam ventilation pipes (from the various steam related texhnical spaces) around the city will be a thing of the past. :)
At least the former seems to actually have been employed or at least studied as an option by ConEd in NYC: https://web.archive.org/web/20071008014254/http://www.coned....
There's a stretch of sidewalk in the Financial District that gets so hot that you can feel it walking past on some days. And apparently, sometimes these things explode... [2]
As far as I've heard it's not (all) actual leaks, though, but rather water dripping on the exterior of the hot pipes carrying the steam itself being evaporated.
[1] https://en.wikipedia.org/wiki/New_York_City_steam_system
[2] https://en.wikipedia.org/wiki/2007_New_York_City_steam_explo...
Maybe the steam pipes keeps the sewers warmer in places with steam but they should be well insulated in the end.
i don't think it's steam leaking. it's drainage/sewer water being heated by the steam system (and other heat sources down there) enough that it evaporates and rises up to the street, and then condenses into vapor/fog because the street level is cooler
Apparently it's to regulate pressure.
In addition to the heating/cooling uses, the mint in Denver uses it to clean coins!
https://news.ycombinator.com/item?id=18430512 (2018)
Holohan argues that we've mostly lost competence at maintaining steam heating systems, and it's not that hard. The lack of understanding has led to many expensive and ineffective refurbishments.
These kinds of stats really irritate me. Sure, smoking isn't great. Breathing in small particulates also isn't great. However, the 18 minutes is such a weird thing. There are so many people that have lived longer lives by smoking than people that work out all the time. There's just no real evidence this stat is true. You can't clone a person and sit one clone in the room with a fireplace, and then the other not in the room. Then watch which one dies first.
The only test I've seen with evidence of one doing something the other doesn't was the twin brother astronauts where one went to space and the other did not.
I'd encourage you to open up one of these studies. The language in scientific papers is made to sound smart but it's still English (most of the time) and you'll see these sorts of things are established by looking at many people in many situations and then use maths to tease out how much each of the factors (living near a major road, for instance) contributes to the thing being investigated (such as longevity). Many of the factors, also depending on the number of people involved, will not turn out to be statistically significant, meaning that the error margins are too large to be sure. For smoking and woodfire particulates though, we're certain that it's unhealthy to within extremely low error margins. Whether that's precisely 18 minutes: probably not, but presumably that's our best guess, even if it has uncertainty associated with it. The paper is linked literally within the quote you gave, if you want to check how uncertain the value is: https://www.sciencedirect.com/science/article/pii/S235271022...
Skimming this one, they didn't establish the relation between particulate matter and lifespan themselves but they cite other studies that did this:
> correlating average PM2.5 levels during a shorter time interval and the average life expectancy during that same time period. In Taiwan, this method used data from 17 counties for the 2010 to 2017 period and resulted in a DLE factor of 0.798 years per 10 μg/m3-increase in exposure to PM2.5 [50]. Using data from 545 counties in the United States for between 2000 and 2007 [51] and data from 214 cities in China for between 2013 and 2017 [52], resulted in lower DLE factors: 0.14 and 0.18 years, respectively, per additional 10 μg/m3 of exposure to PM2.5.
If you doubt those methods, you should click through to sources 50, 51, and 52. This study just measured the amount of PM2.5 in three situations and then multiplied it with that value from the other studies (I didn't read far enough to see which one they ended up picking, that should be mentioned somewhere if you want to know/check it precisely), and that's how they get to this value
> There's just no real evidence this stat is true.
They don't just pull stats from thin air. If you think they made a mistake somewhere and arrived at the wrong number, I'm curious to hear where they went wrong, and the authors would probably be happy to be get an even better stat as well
This did make me chuckle
> reduces your lifespan by about 18 minutes
As George Carlin said, "yeah, but it's the last 18 minutes".
So the other 45 cubic feet exhaust per minute go where? Into the rooms to suffocate the people there?
But what counteracts this is a loss in humidity caused by the heating of cold air from the radiator itself (cold air warmed up reduces relative humidity), and in my experience, this more than counteracts the little bit of steam hissing out of the radiator valve.
As a side note, I've always wondered if the steam being vented that way is actually coming from the steam plant, or whether there's a heat exchanger somewhere in between that isolates a building's steam network from the distribution one (which is the case for liquid water heating, as far as I understand).
Historically, you open a window.
inside the pipe, can much life survive? is there anything to eat in there? has anything evolved specifically to live in NYC steam pipes?
You should be more worried about Legionella, but proper steam and hot water systems will stay above 140F (60C) as that temperature not only prevents the bacteria from multiplying but will kill 90% of them within 2 minutes.
This is located in the basement of one of the buildings on campus. The power plant consists of three Ames Iron works single piston steam generators producing 120V DC fed to a marble switch board. Another piece is an early non-functioning steam turbine DC generator, WW2 era diesel generator from a battle ship. A 30HP motor-generator set used to provide 120V DC to the two service elevators in the building. And in the boiler room are numerous antique yet still functioning feed water pumps (the original steam driven feed water pumps actually do most of the work with newer electric pumps kept for standby) On the wall of the boiler room is a functional steam driven Ingersoll Rand air compressor. Amazing place. When I first visited in the 90's the MG set was still running providing power to the service elevators though they were replaced in the 00's leaving the MG set idle. There is also an old giant wood and brass Master clock in the office that was wired to every other clock on campus so whatever time you set on the master, the other clocks would then run super fact until they come around to the set time. It was running up to the 80's I think but Milster said a renovation crew hacked up all the wiring and no one ever bothered to fix it.
Milster was fired a few years ago supposedly after he refused to remove the resident stray cats who lived in the plant (they even had their own little decorated doorway.) The reason being a union employee was allergic to the cats and kept complaining until they fired him. Shame because anyone who works with antique steam equipment knows Milster and hes full of ancient knowledge no one will ever regain.
Edit: If you are into steam then look up Conrad Milster. I had the pleasure of talking to him a few times and he's such a nice and knowledgeable individual. He even started one of the 120V generators just for me after I said "Wish I could see it run" and he was like "sure" then opens a valve and slowly opens another to get it up to speed. Scary as the inertial lever arm bangs around loudly in the flywheel but then its goes near silent and hums away. Steam engines are very quiet.
(carries a nuclear pellet around) just add water
The photo of this explosion makes it look huge. I wonder how much the pent up infrastructure work to avoid these issues would cost. Are water or gas pipes also vulnerable to this sort of thing?
The cost is essentially incalculable. Back in the 1800s people kept poor records of what they were stuffing under the streets, and the records that were kept were lost, and the ones that weren't lost are sitting in a box who knows where. NYC has effectively no idea what they're going to find under a street every time they tear one up, and the deeper you dig, the more you find.
That isn't to say water/fluids are not dangerous. They can kill. However for the same pressure gases are much worse.
The wikipedia article has a few more photos: https://en.wikipedia.org/wiki/2007_New_York_City_steam_explo...
The aftermath photo gives you a good sense of it: https://www.nbcnews.com/id/wbna20184563