Power plants are all over, even in populated areas. They’re not so bad either (except perhaps coal).
There is no fundamental reason that datacenters need to be especially unpleasant to their neighbors.
Power plants are all over, even in populated areas. They’re not so bad either (except perhaps coal).
There is no fundamental reason that datacenters need to be especially unpleasant to their neighbors.
But that is not how corporations roll. They want the cheapest shit that they can get away with. No regulations only corruption. Which is middle of nowhere America.
What I don't understand is putting these things in populated areas.
Besides, it's not about people, it's about power. Pulling a few MW into middle of nowhere is prohibitively expensive.
The idea of building robust, lightly-staffed technical facilities in obscure places all over the country is nothing even remotely new. It's how the long-distance telephone network was constructed and successfully operated in the decades before satellites took over: https://telephoneworld.org/long-distance-companies/att-long-...
Sure there is, being a good neighbor costs more than being a bad neighbor
I don't have any datacenters near me but I can hear some heavy hums from the washing machine 3 floors up when it put my head on my pillow, for some reason it just propagates through the building physically. When I walk around I don't hear it. Datacenter noise can be the same.
IMO they should be put away from habitation, there's no reason for them to be near there anyway
I agree, but that's a hard problem (in the US anyway). Unless you're plopping data centers in the middle of national parks, or in the middle of the desert where water is going to be a problem, you are nearly always going to be within some small mile radius of civilization. Plus the cost of trenching new fiber out in the middle of nowhere.
The same reasons humans want to concentrate in a particular area (access to jobs, infrastructure) are the same things that data centers need.
Once water-less cooling tech like this improves then yeah, just plopping them in the middle of the unpopulated desert becomes viable (assuming you can get the fiber out there and latency is tolerable), so long as they generate their own power.
Imo we should just solve the problems with data centers being near cities. Manage/regulate the noise and any waste (heat included, it shouldn't drastically impact the neighbors) and make them pay for any utility capacity/reliability upgrades needed. If this article is right and water usage can be nearly eliminated then it seems like the rest should be solvable? Especially if we can take the extra heat and use it for local power or heating needs.
If you cycle between 45 C and 55 C water temperature (as mentioned by the press release), you are only getting a 10 C delta. That isn't even enough for district heating, probably not even with heat pumps.
Now if you have something like a steel foundry, that have much hotter cooling water, you can absolutely use the heat for district heating, but even then it usually isn't enough for cost effective electricity generation. Even when it is waste heat, as the equipment to handle it still costs money and requires maintenance.
You are calculating the wrong delta T. To heat a space, you need your working fluid to be warmer that the space you’re heating by an appropriate amount.
55°C is certainly on the cool side to heat a building, but it’s entirely workable with a high-area, highish-thermal-conductivity system. Here’s an actual chart:
https://www.warmboard.com/wp-content/uploads/2022/04/WaterTe...
You don’t actually want an absurdly warm floor.
Even for buildings that need warmer fluid, water at 45-55°C is a fantastic source for a heat pump.
There low-temp/cold DH systems out there that rely on heatpumps in the buildings to extract the heat. Less losses in the network and you can even use them for cooling, but needs heat pumps everywhere.
In comparison, a traditional heat exhanger is pretty simple technology; just a hunk of metal with a valve.
Right. Vibration propagates through solid (and liquid) materials.
But this can all be measured and controlled, and there's nothing special about datacenters. A building that is hundreds of feet away will couple to your pillow much less strongly than a washing machine in your building. And the washing machine often has a wildly unbalanced load and minimal decoupling between itself and the floor, whereas a big fan in a datacenter or other industrial building ought to be balanced and also ought to be installed on decoupling mounts.
If datacenter operators (cough xAI) are being lazy about properly selecting, installing and maintaining equipment, then you can have a problem. Otherwise you have a much smaller problem.
People said this about high voltage electric lines and wind turbines. Blind tests proved they were imagining things.
https://blog.andymasley.com/p/contra-benn-jordan-data-center...
At no point in his video does Benn claim to be representing the consensus. The whole premise of his videos is that he is introducing something for which there is very little consensus! Each paper has its own conclusions, which don't have to be the same as Benn's. This whole thing boils down to an attack on Benn's character ability to draw meaningful conclusions on his own.
I am not.
Benn claims that the papers say one thing when in fact, if you read them (even the abstracts), they mostly say the exact opposite. It's that simple.
I thought it was a joke of some kind and eventually he would give the "reveal" but no, he finished the video without ever considered that USB is a host/device connection - and although USB-C confusingly introduced a symmetric cable, you cannot connect two devices back-to-back (one end has to be a host) and expect anything useful to happen. And that's why Apple sells a "camera" kit to allow an iPad to act as the host to USB devices.
Seeing him use an oscilloscope to diagnose an Ethernet issue in an earlier video had given me the expectation that he was technically knowledgeable and interesting. So it was shocking that he could present conclusions with such a confident and knowledgeable air, having missed such a basic and fundamental fact about USB.
And there was no push back in the comments that I could see at the time - so seemingly half a million viewers would have finished the video feeling they had learnt something.