If it doesn't why not just make the whole 100 mile stretch of canals discussed a single very long daisy chain of panels, and still address the concern of the OP in terms of extra material for conductors?
If it doesn't why not just make the whole 100 mile stretch of canals discussed a single very long daisy chain of panels, and still address the concern of the OP in terms of extra material for conductors?
While having 12kV going through panels is not safe for many reasons, having 300V at 10-20A is completely normal.
12kV is impractical because these voltages can jump quite far, and you need a lot of insulation for them to be safe.
You would have short strings of panels and small string inverters built every ~100 meters along the channel. Inverters will also connect to the high-voltage bus cable, likely buried in a trench along the channel. And most channels in California are not gravity-fed, so they already need pump stations along the way and have power distribution systems for them.