I think it is mostly Google using his picture with the incorrect description below. I feel that is harder to catch for someone taking a quick glance than if the correct picture was used.
330 karma · joined March 6, 2019
I think it is mostly Google using his picture with the incorrect description below. I feel that is harder to catch for someone taking a quick glance than if the correct picture was used.
Those aren't mutually exclusive. You can complain a lot but not be a jerk. You just have to understand and acknowledge the situation the customer service rep is in but still be firm on what you want.
I haven't migrated from python2->3 however I've worked on projects in both. I think a "python2+3" version would have helped. With both APIs in place new code can be written the new way and old code can be migrated as it is touched. Having the ability to incrementally change code I think encourages the transition since you won't end up with a pile of broken code.
I agree this case is taking an anti-competitive action and spinning it into a pro-privacy case. However, what's the line? Personally I believe if you apply the rules equally to competitors and non-competitors alike you can restrict programmatic access to public data. Since LinkedIn isn't doing that, HiQ shouldn't be restricted.
In any case I think this is a poor use of the CFAA.
Not totally but more then other posters on HN that were making claims without research. The NERC report will be totally reliable but that will take 6+ months. And if my conclusions are wrong, they're wrong and I'll update my blog.
> I'm not sure why you want to use layman as a measuring stick.
I made this post as a direct response to previous HN and Reddit posts where the layman were forming conclusions. I did not see a single person quoting or referencing a single standard to back up their claims. I went out looking for something to back up claims and this is what I found. I formed conclusions off this and included them.
If an expert was to tell me I'm wrong and show me what I missed I would be happy to update my blog.
I included the first paragraph just to show that the post was not an expert opinion and was what I found after some research.
https://atomicinsights.com/south-texas-project-unit-1-trippe...
> The trip resulted from a loss of feedwater attributed to a cold weather-related failure of a pressure sensing lines to the feedwater pumps, causing a false signal, which in turn, caused the feedwater pump to trip.
I am not... "I am a software developer, and this is my best interpretation of the requirements I could find"
> The way it is written it seems like they just did a bunch of searches and found some information.
That is about how that went.
> Do they know enough to be sure they're drawing the right conclusions based on what they found?
Maybe? if you have other conclusions, I'd love to hear them.
I agree that the natural gas does not directly go to the station. However, from what I could tell in the NERC documents they referenced it freezing at or close to the well.
> Natural gas at the burner tip is supposed to be one million cubic feet (MCF) is one million BTU (MMBTU)
I'm guessing you're referencing "14.8 Bcf of natural gas production was lost". If so, Bcf comes directly from the NERC report in reference 14.
That isn't really what's needed. If I understand the problems with the gas supply in these events, the issue is the wellhead freezing off due to the high water vapor content in the gas.
Not exactly true. SPP the grid operator for OK and the area immediately east of Texas did have to go to EEA3 twice and implement rolling blackouts
https://spp.org/markets-operations/current-grid-conditions/
>Feb. 15 at approximately 12:10 pm. While still under EEA Level 3 and after exhausting reserves, SPP directed member utilities to implement controlled, temporary interruptions of service.
>Feb. 16 at 6:15 a.m. SPP declared an EEA Level 3. System-wide generating capacity had dropped below current load of approximately 42 gigawatts (GW) due to extremely low temperatures, inadequate supplies of natural gas and wind generation. SPP directed member utilities to implement controlled, temporary interruptions of service.
> Feb. 16 at 6:15 a.m. SPP declared an EEA Level 3. System-wide generating capacity had dropped below current load of approximately 42 gigawatts (GW) due to extremely low temperatures, inadequate supplies of natural gas and wind generation. SPP directed member utilities to implement controlled, temporary interruptions of service.
for posterity:
DC Tie Flows
DC_E (East) -595
DC_L (Laredo VFT) 0
DC_N (North) -218
DC_R (Railroad) 0
DC_S (Eagle Pass) 0Exactly. I'm not sure that even the new NERC regulations for winter weatherization go far enough. They seem to bring NERC standards closer to Texas'.
I couldn't find specific instances of Texas load shedding devices having issues. However, there were instances of things like circuit breakers failing open in very cold weather. This was probably another cause of these very long outages.
Yes. That grid operator did have to implement EEA3 load shedding (rolling blackouts). However, I should note that the Texas rolling blackout seemed to go wrong when they tried to bring locations back online.
The NERC recommendations are requirements in Texas. There is the requirement to plan for extreme winter weather events in Texas but not in NERC.
In 2014 the polar vortex brought power down across the Eastern Interconnection (citation 13) and again in 2018 (citation 10).
> That suggest to me the national regulator has these extreme weather events covered.
There currently are not standards for winter weatherization. In 2013 standards were proposed for this however they were rejected (citation 15). Finally in 2020 standards started the approval process however they wont be fully approved until November.