Unfortunately transistor performance can vary quite widely for a single design; recall that a single CPU mask design is often sold in several speed grades. These aren't different designs, they are all the exact same design but then tested to pass at a given frequency and power profile.
My intuition is that a simple implant would probably escape power characterization, and larger implants can be left off until a trigger condition is met. That condition could be made so that fuzzing is highly unlikely to hit it, e.g. a particular 64-bit number pattern has to appear in a given register to power on the implant.
The technique may be suitable to detect gross anomalous execution in a single well-characterized chip but I feel any robust criteria against false positives would also leave a sufficiently large margin for small implants to slip through undetected.