That's part of it, but linearity and the device's own return loss (a good cal kit can only do so much) are also substantial factors.
Yes, return loss and directivity of the bridges/directional couplers in there is a big factor. It directly corresponds to usable dynamic range after calibration. If your directivity is only 20 dB at 6 GHz, 110 dB of dynamic range at the detector won't do anything for the quality of the final measurement. So an honest way of specifying dynamic range would be for a fully calibrated device. Giving that they say it has 110 dB, I don't think that's the case here.