Regardless, indoor TVOC levels increase significantly over 2-3 days. Then opening the windows brings them back down. Not sure if that's normal. (TVOC = Total volatile organic compounds)
Any recommendations for quality sensors?
Regardless, indoor TVOC levels increase significantly over 2-3 days. Then opening the windows brings them back down. Not sure if that's normal. (TVOC = Total volatile organic compounds)
Any recommendations for quality sensors?
Additionally the sensors are only showing you correct absolute levels in lab conditions, e.g. using ethanol at a specific temperature and humidity. So in real environments, the absolute values are pretty useless.
We now use a newer generation of TVOC senor e.g. the SGP41 that is more index based and eliminates the issue of the absolute values.
We also observe that temperature and humidity can influence the TVOC measurements.
All in all, TVOC is good to detect spikes and check what is causing these, e.g. use of aggressive cleaning chemicals. However the absolute levels in e.g. ppb should better be ignored.
Yes, it is normal that fresh air flushes out chemicals and you can see this improvement. We do like the SGP4x series from Sensirion for TVOC sensors.
A better approach would be to sample consistently and use that to build a graph showing TVOC ppm over time.