Then someone puts two space heaters at the end of their branch circuit, they could easily exceed 20A without tripping the breaker and without straining incredulity.
And you are right, 40A was a silly choice, I figured bigger numbers made it more obvious the problem. But it's not hard to construct a likely example on a 20A circuit either.
In the UK you typically make a ring circuit. In the US you make branching circuits.
In the US you get: Mains -> Breaker -> Outlet 1 -> Outlet 2 -> Outlet 3.
In the UK you get: Mains -> Breaker -> all outlets -> Breaker
In the US, assume I had 65A of load on outlet 3 -- I've plugged in too many things into a surge protector. Assume a bunch of solar panels are on outlet 1.
The the diagram looks like: Mains -40A-> Breaker -40A-> Outlet 1 -65A-> Outlet 2 -65A-> Outlet 3
Now, the breaker won't trip because only 40A are crossing the breaker. But 65A are on the wire between outlet 1 and 2 and between 2 and 3.
Do you have these glasses and it makes you upset that you are perceived as a perv? Do you work on perv glasses? It's very surprising to respond so strongly to white knight for an obviously creepy escalation of surveillance and recording technology.
Your circuit breaker protects your circuits by putting all the load (eg your microwave) on one side, and your supply (mains power) on the other. If too much load is present, the circuit breaker trips.
However, plugin solar puts invisible supply on the load side, which your circuit breaker cannot see. Let's make an absurd example so you can see what the problem is, then scale it back.
Imagine someone buys 5 panels that can each supply 5amps. They plug them into outlets on a 40 amp circuit. They then proceed to run their toaster, microwave, vacuum, and hair dryer. They can draw 65 amps through the wires before the circuit breaker trips. (40 from mains, 25 from the panels)
Let's say they had a good electrician who installed 6AWG wiring on that circuit, which is rated for 50 amps. The circuit breaker used to trip at 40, so no problem. But now up to 65 can go across the wires and suddenly you are exceeding rating for wires.
Now you might say, "most of these are 3.5 watts, and they clearly say don't use more than one". But I say that's a "good intentions solution". We should make it mechanically impossible to do the wrong thing. Maybe these panels could try to communicate over the electrical wires, and if they detect a signal from another panel they should self limit. Maybe we need to rethink circuit panel design. But as it stands people will absolutely buy one of these, decide they love it, and then buy 4 more.
It's a risk. A very small one. You gotta figure out your tolerance for risk.
I have two gorgeous sleeves with deep meaning, that I put hours and hours of pain in to. But they are for me. I love the art, I love carrying that art. I don't care about how they scan to others.
It has nothing to do with being cool or fitting in.
Take a moment and try to understand before you construct such obviously silly and banal statements.
I've commissioned tons of art, and one of the great joys is the surprise at how they interpret your idea, and how it's always different than what you had in your mind. That joy is unique to commissioned art, I think.